WebBispectral Index™ (BIS™) monitoring enhances the clinician’s patient-targeted approach to induction, maintenance, and emergence. BIS™ technology non-invasively measures … The BIS monitor provides a single dimensionless number, which ranges from 0 (equivalent to EEG silence) to 100. A BIS value between 40 and 60 indicates an appropriate level for general anesthesia , as recommended by the manufacturer. See more Bispectral index (BIS) is one of several technologies used to monitor depth of anesthesia. BIS monitors are used to supplement Guedel's classification system for determining depth of anesthesia. Titrating See more The bispectral index is a statistically based, empirically derived complex parameter. It is a weighted sum of several electroencephalographic … See more BIS monitoring is widely used in operating rooms and ICUs, as well as in emergency departments. Some of the benefits that have been attributed to it include: • Reduced time to extubation and discharge from the operating room and PACU See more • Anaesthetic machine • Entropy monitoring • Evoked potentials • Respiratory monitoring • Spectral edge frequency See more The BIS was introduced by Aspect Medical Systems, Inc. in 1994 as a novel measure of the level of consciousness by algorithmic analysis of a patient's electroencephalogram during general anesthesia. This is used in conjunction with other … See more Some of the limitations of this form of processed EEG monitoring are: • Unreliability with certain drugs, such as ketamine, nitrous oxide and ephedrine. Ketamine may … See more The BIS is an electroencephalogram-derived multivariant scale that, when a drug such a propofol is used, correlates with the metabolic rate of glucose. Both loss of … See more
BIS Monitor
Web710 Medtronic Parkway. Minneapolis, MN. 55432-5604. USA. ©2024 Medtronic WebBispectral index (BIS) for improving intraoperative awareness and early postoperative recovery in adults Background During surgery under general anaesthesia, the anaesthetist will adjust the amount of anaesthetic drugs to ensure that the patient remains unconscious. how many people can fit in a ford edge
Bispectral index for improving intraoperative awareness and early ...
WebNov 21, 2012 · This provides a direct measure of the patient's response to anaesthetic drugs. The target range of BIS values during general anaesthesia is 40 to 60; this range … WebSep 19, 2024 · BIS value is usually maintained between 40 to 60 to prevent awareness under anesthesia. Technique BIS monitoring involves the application of four electrodes on the forehead. The skin on the forehead … how can i get a letter with my ni number